160
Intera 5.3
typically fall between 0.8 and 1.5 m/s. That said, the speed for an individual movement can be set in
the software, and can be tailored to the specific task.
Figure D-3: Chart showing the endpoint velocity for a specific task. This task is designed for maxi-
mizing speed at the endpoint. J0 and J2 are set to rotate around the base for a 180 degree move-
ment. The joint acceleration setting is set to
express
in the Intera software.
For more information regarding speed as it relates to safety standards, please see
Sawyer Safety
Overview: Safety by Design
.
E-Stop Performance
When an emergency stop is performed, the power is cut to the arm at the motor level, and the robot
stops wherever it is in the task. To assess the performance of the E-Stop, two metrics have been
analyzed, settling time and overshoot.
Settling Time - The settling time is defined to be the steady state time minus the time at which the
E-Stop was triggered.
Summary of Contents for Sawyer
Page 15: ...8 Intera 5 3 Getting to Know Sawyer Hardware Overview of Your Robot ...
Page 16: ...9 Intera 5 3 Getting to Know Sawyer Dimensions ...
Page 17: ...10 Intera 5 3 Getting to Know Sawyer Sawyer Reach ...
Page 93: ...86 Intera 5 3 Train Pick and Place Patterns on the Head 11 Press OK to go to the next step ...
Page 104: ...97 Intera 5 3 Train Pick and Place Patterns on the Head You may now run the task ...
Page 134: ...127 Intera 5 3 TCP IP The Set To node in the Behavior Editor is used to output information ...
Page 138: ...131 Intera 5 3 Fieldbus Devices 3 Using a keyboard navigate to CONFIGURATION and press ENTER ...
Page 155: ...148 Intera 5 3 ...
Page 156: ...149 Intera 5 3 ...
Page 180: ...173 Intera 5 3 ...
Page 190: ...183 Intera 5 3 Fixed Data 112 From Robot ...
Page 206: ...199 Intera 5 3 Small Assembly 114 From Robot 115 To Robot ...
Page 207: ...200 Intera 5 3 Large Assembly 116 From Robot 117 To Robot ...
Page 208: ...201 Intera 5 3 Floats 118 From Robot 119 To Robot ...
Page 209: ...202 Intera 5 3 Strings 120 From Robot 121 To Robot ...
Page 218: ...Z Zero G button 16 17 Zero G mode 24 Zero Gravity mode 17 zoom reset 42 ...
Page 219: ......
Page 220: ...Last updated June 18 2018 Intera 5 3 User Guide Getting Started Rev A ...