Rev. 2.00, 09/03, page 578 of 690
23.4
Operation
23.4.1
TAP Controller
Figure 23.2 shows the internal states of the TAP controller. State transitions basically conform to
the JTAG standard.
Test-logic-reset
Capture-DR
Shift-DR
Exit1-DR
Pause-DR
Exit2-DR
Update-DR
Select-DR-scan
Run-test/idle
1
0
0
0
0
1
1
1
1
0
0
1
0
1
1
1
0
Capture-IR
Shift-IR
Exit1-IR
Pause-IR
Exit2-IR
Update-IR
Select-IR-scan
0
0
1
0
0
1
1
0
1
1
1
0
0
Figure 23.2 TAP Controller State Transitions
Note:
The transition condition is the TMS value at the rising edge of TCK. The TDI value is
sampled at the rising edge of TCK; shifting occurs at the falling edge of TCK. For details
on change timing of the TDO value, see section 23.4.3, TDO Output Timing. The TDO is
at high impedance, except with shift-DR and shift-IR states. During the change to
TRST =
0, there is a transition to test-logic-reset asynchronously with TCK.
Summary of Contents for SH7705
Page 2: ......
Page 70: ...Rev 2 00 09 03 page 24 of 690 ...
Page 194: ...Rev 2 00 09 03 page 148 of 690 ...
Page 284: ...Rev 2 00 09 03 page 238 of 690 ...
Page 338: ...Rev 2 00 09 03 page 292 of 690 ...
Page 354: ...Rev 2 00 09 03 page 308 of 690 ...
Page 374: ...Rev 2 00 09 03 page 328 of 690 ...
Page 420: ...Rev 2 00 09 03 page 374 of 690 ...
Page 476: ...Rev 2 00 09 03 page 430 of 690 ...
Page 482: ...Rev 2 00 09 03 page 436 of 690 ...
Page 552: ...Rev 2 00 09 03 page 506 of 690 ...
Page 630: ...Rev 2 00 09 03 page 584 of 690 ...
Page 739: ...SH7705 Group Hardware Manual REJ09B0082 0200O ...