Rev. 2.00, 09/03, page 120 of 690
•
Save address
A delayed branch instruction address
•
Exception code
H'1A0
•
Remarks
None
Unconditional Trap:
•
Conditions
TRAPA instruction executed
•
Types
Instruction synchronous, processing-completion type
•
Save address
An address of an instruction following TRAPA
•
Exception code
H'160
•
Remarks
The exception is a processing-completion type, so PC of the instruction after the TRAPA
instruction is saved to SPC. The 8-bit immediate value in the TRAPA instruction is quadrupled
and set in TRA[9:2].
User Break Point Trap:
•
Conditions
When a break condition set in the user break controller is satisfied
•
Types
Break (L bus) before instruction execution: Instruction synchronous, re-execution type
Operand break (L bus): Instruction synchronous, processing-completion type
Data break (L bus): Instruction asynchronous, processing-completion type
I bus break: Instruction asynchronous, processing-completion type
•
Save address
Re-execution type: An address of the instruction where a break occurs (a delayed branch
instruction address if an instruction is assigned to a delay slot)
Processing-completion type: An address of the instruction following the instruction where a
break occurs (a delayed branch instruction address if an instruction is assigned to a delay slot)
•
Exception code
H'1E0
Summary of Contents for SH7705
Page 2: ......
Page 70: ...Rev 2 00 09 03 page 24 of 690 ...
Page 194: ...Rev 2 00 09 03 page 148 of 690 ...
Page 284: ...Rev 2 00 09 03 page 238 of 690 ...
Page 338: ...Rev 2 00 09 03 page 292 of 690 ...
Page 354: ...Rev 2 00 09 03 page 308 of 690 ...
Page 374: ...Rev 2 00 09 03 page 328 of 690 ...
Page 420: ...Rev 2 00 09 03 page 374 of 690 ...
Page 476: ...Rev 2 00 09 03 page 430 of 690 ...
Page 482: ...Rev 2 00 09 03 page 436 of 690 ...
Page 552: ...Rev 2 00 09 03 page 506 of 690 ...
Page 630: ...Rev 2 00 09 03 page 584 of 690 ...
Page 739: ...SH7705 Group Hardware Manual REJ09B0082 0200O ...