uREG User Manual
85
Backlight will be resumed automatically when the display is cooled down.
…
…
Reserved
112
70
5V → Motherboard (MB) supply below +4.75 V
113
71
5V → Motherboard (MB) supply e5.25 V
114
72
3.3V → Motherboard (MB) supply below +3.20 V
115
73
3.3V → Motherboard (MB) supply e3.40 V
116
74
Failed -12V → Motherboard (MB) supply below -14 V
117
75
Failed -12V → Motherboard (MB) supply exceeds -10 V
118
76
12V → Motherboard (MB) supply below +10 V
119
77
12V → Motherboard (MB) supply e14 V
120
78
Motherboard (MB) temperature below normal
121
79
Motherboard (MB) temperature exceeded
Display backlight will be turned off.
Backlight will be resumed automatically when the display is cooled down.
…
…
Reserved
128
80
Failed counters → Faulty readout of counters
129
81
Missing SLOTOCCUP → Failed collection of module configuration
130
82
Netlist error → Failed Netlist initialization
131
83
Failed SLOTOCCUP → Incompatibility between module configuration and application
132
84
Failed SPI → Failed SPI bus – No communication with MB
133
85
MB fault → MB Hard fault exception
…
…
Reserved