Remote Control Commands
R&S
®
SGT100A
481
User Manual 1176.8674.02 ─ 07
:SYSTem:COMMunicate:NETWork:STATus?
Queries the network configuration state.
Return values:
<State>
0 | 1 | OFF | ON
Usage:
Query only
:SYSTem:COMMunicate:NETWork:RESTart
Restarts the network connection to the instrument, terminates the connection and sets
it up again.
Example:
SYSTem:COMMunicate:NETWork:RESTart
Usage:
Event
:SYSTem:COMMunicate:NETWork[:COMMon]:HOSTname
<Hostname>
Sets the individual host name of the R&S
SGT.
Note:
it is recommended that you do not change the host name in order to avoid prob-
lems with the networdk connection. However, if you change the host name be sure to
use an unique name.
The host name is a protected parameter, To change it, first disable protection level 1
with command
Parameters:
<Hostname>
string
Example:
SYSTem:PROTect1:STATe OFF,123456
SYSTem:COMMunicate:NETWork:HOSTname 'SIGGEN'
sets the individual computer name of the R&S
SGT.
Manual operation:
See
:SYSTem:COMMunicate:NETWork[:IPADdress]:DNS
<DNS>
Determines or queries the network DNS server to resolve the name.
Parameters:
<DNS>
string
Example:
SYST:COMM:NETW:IPAD:DNS?
Response:
"10.0.1.11"
:SYSTem:COMMunicate:NETWork[:IPADdress]:GATeway
<Gateway>
Sets the IP address of the default gateway.
SYSTem Subsystem