Remote Control Commands
R&S
®
SGT100A
442
User Manual 1176.8674.02 ─ 07
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:POWer:OFFSet?
Queries the current power offset, that is the sum of enabled "RF Level > Offset" and
"User Correction".
Return values:
<PowerOffset>
float
Range:
-200 to 200
Increment: 0.01
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:SHAPing:MODE
<ShapingMode>
Enables envelope shaping and selects the method to define the shaping function.
Parameters:
<ShapingMode>
OFF | LINear | TABLe | POLYnomial | DETRoughing | POWer
LINear
= Linear (Voltage)
POWer
= Linear (Power)
*RST:
OFF
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:SHAPing:SCALe
<Scale>
Determines the units used on the x and y axis.
Parameters:
<Scale>
POWer | VOLTage
*RST:
VOLTage
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
SOURce Subsystem