Remote Control Commands
R&S
®
SGT100A
440
User Manual 1176.8674.02 ─ 07
Parameters:
<VccMax>
float
Range:
0.04 to 8
Increment: 0.001
*RST:
1
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:VALue:PEP?
Queries the Vcc value of the current PEP of the generated RF signal.
Return values:
<VccForCrtPep>
float
Range:
0 to 38
Increment: 1E-3
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:VALue:LEVel?
Queries the Vcc value of the current RMS power level (operating point).
Return values:
<VccForRfLevel>
float
Range:
0 to 38
Increment: 1E-3
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:VCC:VALue?
<xValue>, <xUnit>,
<xScale>
Queries the V
CC
value for the selected
<xValue>
.
SOURce Subsystem