Remote Control Commands
R&S
®
SGT100A
441
User Manual 1176.8674.02 ─ 07
Query parameters:
<xValue>
float
Value on the x-axis
Value range depends on the selected "Envelope Voltage Adap-
tation" and PEP
in
Min and PEP
in
Max values.
<xUnit>
NORMalized | DBM | V
*RST:
NORMalized
<xScale>
VOLTage | POWer
*RST:
VOLTage
Return values:
<VccValue>
float
Range:
0 to 38
Increment: 1E-3
*RST:
0
Example:
See
Example "Generating an RF envelope signal and defining
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:PIN:MIN
<PinMin>
Sets the minimum value of the input power P
in
.
Parameters:
<PinMin>
float
Range:
-145 to 20
Increment: 0.01
*RST:
-30
Example:
See
Example "Generating an RF envelope signal and defining
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:PIN:MAX
<PinMax>
Sets the maximum value of the input power P
in
.
Parameters:
<PinMax>
float
Range:
-145 to 20
Increment: 0.01
*RST:
-20
Example:
See
Example "Generating an RF envelope signal and defining
SOURce Subsystem