Signal Generator Settings
R&S
®
SGT100A
116
User Manual 1176.8674.02 ─ 07
"Same Segment"
Depending on the trigger setting, the currently selected segment is
continuously output either immediately or after a trigger event.
Signal generation takes place differently according to the trigger
selected in the "Trigger In" section:
●
In the case of "Trigger = Auto", output starts at once and the seg-
ment is generated continuously. Trigger events are ignored.
If the segment is changed in "Next Segment", output of the cur-
rent segment is stopped and the new segment is output immedi-
ately, following a system-imposed signal gap (see above).
●
In the case of "Trigger = Armed_Auto", output starts after the first
trigger event. The segment is then generated continuously. Fur-
ther trigger events are ignored.
If the segment is changed in "Next Segment", signal output is
stopped and the new segment is not output until a trigger occurs.
●
In the case of "Trigger = Retrigger", output starts at once and the
segment is generated continuously, a trigger event causes a
restart.
If the segment is changed in "Next Segment", output of the cur-
rent segment is stopped and the new segment is output immedi-
ately, following a system-imposed signal gap (see above).
●
In the case of "Trigger = Armed_Retrigger", output starts after the
first trigger event. The segment is then generated continuously.
Further trigger events cause a restart.
If the segment is changed in "Next Segment", signal output is
stopped and the new segment is not output until a trigger occurs.
●
In the case of "Trigger = Single", output starts after the first trigger
event. The segment is then generated once. Further trigger
events cause a restart.
If the segment is changed in "Next Segment", signal output is not
stopped. The new segment is not output until a trigger occurs.
Baseband