Remote Control Commands
R&S
®
SGT100A
374
User Manual 1176.8674.02 ─ 07
Parameters:
<Mode>
OFF | MIN | MAX
OFF
There is no automatic setting for minimizing or maximizing the
crest factor. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is in use.
MIN
The crest factor is minimized by internally calculating optimized
carrier phases. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is invalid.
MAX
The crest factor is maximized by internally calculating optimized
carrier phases. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is invalid.
*RST:
OFF
Example:
BB:ARB:MCAR:CFAC:MODE OFF
switches off automatic crest factor optimization. The setting
SOUR:BB:ARB:MCAR:CARR:PHAS
has an effect.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping:CFACtor
<CFactor>
Sets the value of the desired crest factor, if baseband clipping is enabled
(
BB:ARB:MCAR:CLIP:STAT ON
).
A Target Crest Factor above the crest factor of the unclipped multicarrier signal has no
effect.
Parameters:
<CFactor>
float
Range:
-50 to 50
Increment: 0.01
*RST:
50
Default unit: dB
Example:
BB:ARB:MCAR:CLIP:STAT ON
enables clipping.
BB:ARB:MCAR:CLIP:CFAC 37 dB
sets the target crest factor.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping:CUToff
<Cutoff>
Sets the cut off frequency of the final lowpass filter, if baseband clipping is enabled
(
BB:ARB:MCAR:CLIP:STAT ON
).
SOURce Subsystem