Remote Control Commands
R&S
®
SGT100A
380
User Manual 1176.8674.02 ─ 07
Parameters:
<Start>
float
Range:
-80 to 0
Increment: 0.01
*RST:
0
Default unit: dB
Example:
BB:ARB:MCAR:EDIT:CARR:POW -50 dB
sets the power of the carriers in the carrier range to -50 dB.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STARt
<Start>
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STOP
<Stop>
The command selects the last carrier in the carrier range to which the settings with
the
:BB:ARB:MCAR:EDIT:CARR:..
commands shall apply.
Parameters:
<Stop>
integer
Range:
0 to 511
*RST:
0
Example:
BB:ARB:MCAR:EDIT:CARR:STOP 4
the carrier range stops at carrier 4.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:STATe
<State>
The command switches all the carriers in the selected carrier range on or off.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
BB:ARB:MCAR:EDIT:CARR:STAT ON
sets all the carriers in the carrier range to ON.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:OFILe
<OFile>
This command defines the output file name for the multi carrier waveform. This file
name is used when a waveform is calculated (command
SOUR:BB:ARB:MCAR:CLOad
or
SOUR:BB:ARB:MCAR:CREate
). The file extension is
*.wv
.
Parameters:
<OFile>
string
SOURce Subsystem