Remote Control
R&S
®
ESR
697
User Manual 1175.7068.02 ─ 12
Example:
INIT:CONT OFF
Switches to single sweep mode.
CALC:MARK2 ON
Switches marker 2.
INIT;*WAI
Starts a sweep and waits for the end.
CALC:MARK2:Y?
Outputs the measured value of marker 2.
In I/Q Analyzer mode, for "Real/Imag (I/Q)", for example:
1.852719887E-011,0
Manual operation:
See
"Marker 1 / Marker 2 / Marker 3 / … Marker 16,/ Marker
11.4.7.3
Using Delta Markers
CALCulate<n>:DELTamarker<m>:AOFF
...........................................................................697
CALCulate<n>:DELTamarker<m>:LINK
............................................................................ 697
CALCulate<n>:DELTamarker<m>:MAXimum:LEFT
........................................................... 698
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT
...........................................................698
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK]
.........................................................699
CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
.......................................................... 699
CALCulate<n>:DELTamarker<m>:MINimum:LEFT
............................................................ 699
CALCulate<n>:DELTamarker<m>:MINimum:NEXT
............................................................700
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK]
.......................................................... 700
CALCulate<n>:DELTamarker<m>:MINimum:RIGHt
........................................................... 700
CALCulate<n>:DELTamarker<m>:MODE
......................................................................... 701
CALCulate<n>:DELTamarker<m>[:STATe]
........................................................................ 701
CALCulate<n>:DELTamarker<m>:TRACe
.........................................................................701
................................................................................. 702
CALCulate<n>:DELTamarker<m>:X:RELative?
................................................................. 702
................................................................................. 703
CALCulate<n>:DELTamarker<m>:AOFF
This command turns all active delta markers off.
Suffix:
<n>
.
Selects the measurement window.
<m>
Selects the marker.
Example:
CALC:DELT:AOFF
Switches off all delta markers.
Manual operation:
See
CALCulate<n>:DELTamarker<m>:LINK
<State>
This command links delta marker 1 to marker 1.
If you change the horizontal position of the marker, so does the delta marker.
Remote Commands in Receiver Mode