Adv a nc e d s y s te m re s e t (10 s e c ):
After pressing the reset button for 10 seconds,
you will hear two beeps at the third and the tenth seconds. The NAS will reset all
the system settings to default as it does by the web-based system reset in
"Administration" > "Restore to Factory Default" except all the data are reserved.
The settings such as the users, user groups, and the shared folders previously
created will be cleared. To retrieve the old data after advanced system reset,
create the same shared folders on the NAS and the data will be accessible again.
E na ble ha rd dis k s ta ndby m ode :
This option allows the hard drives on the NAS to
enter standby mode if there is no disk access within the specified period.
E na ble light s igna l a le rt whe n the fre e s ize of SATA dis k is le s s tha n the
v a lue :
The status LED flashes red and green when this option is turned on and the
free space of the SATA hard drive is less than the value. The valid range of the
value is 1-51200 MB.
E na ble write c a c he (E X T4 only ):
If the disk volume of the NAS is formatted as
EXT4, turn on this option for higher write performance. Note that an unexpected
system shutdown may lead to incomplete data transfer when data write is in
process. This option will be turned off when any of the following services is
enabled: Download Station, MySQL service, user quota, and Surveillance Station.
You are recommended to turn this option off if the NAS is set as a shared storage in
a virtualized or clustered environment.
E na ble wa rning a le rt for re dunda nt powe r s upply on the we b- ba s e d
inte rfa c e :
If two power supply units (PSU) are installed on the NAS and connected
to the power sockets, both PSU will supply the power to the NAS (applied to 1U and
2U models). Turn on the redundant power supply mode in "System Settings" >
"Hardware" to receive warning alert for the redundant power supply. The NAS will
sound and record the error messages in "System Logs" when the PSU is plugged out
or does not correspond correctly. If only one PSU is installed on the NAS, do NOT
enable this option. Note that this function is disabled by default.
Buz z e r
E na ble a la rm buzze r:
Turn on this option to allow the alarm buzzer to beep when
certain system operations (startup, shutdown, or firmware upgrade) are executed or
system events (error or warning) occur.
W rite C a che