D-258
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
165.17 CUST NAME 3
CUSTOM TRIPS
STRING max length is 16 chars
rw
165.18 CUST NAME 4
CUSTOM TRIPS
STRING max length is 16 chars
rw
165.19 CUST NAME 5
CUSTOM TRIPS
STRING max length is 16 chars
rw
165.20 CUST NAME 6
CUSTOM TRIPS
STRING max length is 16 chars
rw
165.21 CUST NAME 7
CUSTOM TRIPS
STRING max length is 16 chars
rw
177.01 RTNX IP ADDRESS ETHERNET
STRING max length is 15 chars
ro
Output
177.02 STATE
ETHERNET
ENUM
0 : UNKNOWN
1 : SETUP
2 : INITIALISATION
3 : WAIT PROCESS
4 : IDLE
5 : PROCESS ACTIVE
6 : ERROR
7 : EXCEPTION
8 : WAIT TO CONNECT
9 : STOPPED
10 : RUNNING
11 : FAULT
12 : NOT ACTIVE
13 : ACTIVE
14 : NOT SUPPORTED
15 : INIT OR PREOP
16 : OPERATIONAL
17 : SAFE-OP
18 : HARDWARE FAIL
UNKNOWN
ro
Output
177.03 890 IP ADDRESS
ETHERNET
STRING max length is 15 chars
ro
Output
177.04 890 SUBNET MASK ETHERNET
STRING max length is 15 chars
ro
Output
177.05 890 GATEWAY
ETHERNET
STRING max length is 15 chars
ro
Output
177.06 FTP ENABLED
ETHERNET
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
177.07 ADMIN ENABLED
ETHERNET
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output