
Programming
D-211
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
64.01 PARAMETER
OPERATOR
MENU 32
PREF
00.00 to B8.01
0
rw
64.02 NAME
OPERATOR
MENU 32
STRING max length is 16 chars
rw
64.03 SCALING
OPERATOR
MENU 32
ENUM
0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE
rw
64.04 READ ONLY
OPERATOR
MENU 32
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
64.05 IGNORE
PASSWORD
OPERATOR
MENU 32
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
65.01 DECIMAL PLACE
DISPLAY SCALE 1 ENUM
0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
DEFAULT
rw
65.02 FORMULA
DISPLAY SCALE 1 ENUM
0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C
rw
65.03 COEFFICIENT A
DISPLAY SCALE 1 REAL
-32768.0000 to
32767.0000
1.0000
rw
65.04 COEFFICIENT B
DISPLAY SCALE 1 REAL
-32768.0000 to
32767.0000
1.0000
rw
65.05 COEFFICIENT C
DISPLAY SCALE 1 REAL
-32768.0000 to
32767.0000
0.0000
rw
65.06 HIGH LIMIT
DISPLAY SCALE 1 REAL
-32768.0000 to
32767.0000
0.0000
rw