D-256
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
161.03 I2T MOTOR LOAD
MOT PMAC
PROTECT
REAL
_.x
0.0 %
ro
Output
161.04 MOTOR I2T TRIP
MOT PMAC
PROTECT
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
161.05 ENABLE
MOT PMAC
PROTECT
BOOL
0 : FALSE
1 : TRUE
TRUE
rw
162.01 AIMING POINT
INVERS TIME
PMAC
REAL
25.00 to 105.00 %
105.00 %
rw
162.02 DELAY
INVERS TIME
PMAC
REAL
0.5 to 60.0 s
4.0 s
rw
162.03 DOWN TIME
INVERS TIME
PMAC
REAL
0.5 to 10.0 s
1.0 s
rw
162.04 UP TIME
INVERS TIME
PMAC
REAL
0.5 to 10.0 s
1.0 s
rw
162.05 IT LIMITING
INVERS TIME
PMAC
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
162.06 INVERSE TIME OP INVERS TIME
PMAC
REAL
_.xx
0.00 %
ro
Output
162.07 IT WARNING
INVERS TIME
PMAC
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
163.01 SELECT TQ COMP
2
SPEED LOOP 2
ENUM
0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE
rw
2
163.02 TQ COMP 2 FREQ
SPEED LOOP 2
REAL
100 to 8000 Hz
2000 Hz
rw
163.03 SELECT TQ COMP
3
SPEED LOOP 2
ENUM
0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE
rw
2
163.04 TQ COMP 3 FREQ
SPEED LOOP 2
REAL
100 to 8000 Hz
2000 Hz
rw