D-250
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
134.24 INERTIA SCALE
MOTOR PMAC 1
ENUM
0 : kgm2
1 : kgcm2
2 : gm2
kgm2
rw
2
134.26 STAND CURRENT
MOTOR PMAC 1
REAL
0.00 to 4096.00 A
10.60 A
rw
2
134.27 THERMAL TIME
CST
MOTOR PMAC 1
REAL
0.00 to 10000.00 s
224.80 s
rw
2
134.28 CUR LOOP BWDTH MOTOR PMAC 1
REAL
100 to 1500 Hz
600 Hz
rw
134.29 INTEGRAL FREQ
MOTOR PMAC 1
REAL
5 to 600 Hz
150 Hz
rw
134.30 KE_REF
MOTOR PMAC 1
REAL
1 to 1000 V
3 V
rw
135.01 MPS1
MOTOR PMAC 2
REAL
0 to 600 V
230 V
rw
2
135.02 MPS2
MOTOR PMAC 2
REAL
0 to 600 V
400 V
rw
2
135.03 MPS3
MOTOR PMAC 2
REAL
0 to 600 V
480 V
rw
2
135.04 CURRENT AT
MPS1
MOTOR PMAC 2
REAL
0.00 to 4096.00 A
10.60 A
rw
2
135.05 CURRENT AT
MPS2
MOTOR PMAC 2
REAL
0.00 to 4096.00 A
10.60 A
rw
2
135.06 CURRENT AT
MPS3
MOTOR PMAC 2
REAL
0.00 to 4096.00 A
10.60 A
rw
2
135.07 SPEED AT MPS1
MOTOR PMAC 2
INT
0 to 2147483647
2300
rw
2
135.08 SPEED AT MPS2
MOTOR PMAC 2
INT
0 to 2147483647
4000
rw
2
135.09 SPEED AT MPS3
MOTOR PMAC 2
INT
0 to 2147483647
4800
rw
2
136.01 DRIVE NAME
DRIVE CONFIG
STRING max length is 14 chars
890 DRIVE
rw
2
136.02 CONTROL MODE
DRIVE CONFIG
ENUM
0 : VOLTS / Hz
1 : SENSORLESS VEC
2 : CLOSED-LOOP VEC
3 : 4-Q REGEN
4 : PMAC
VOLTS / Hz
rw