6-12
Safe Torque Off
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Output Specification
OFF state:
Maximum applied voltage:
+30V (X11/06 relative to X11/05)
Reverse voltage protection:
Up to -30V X11/06 relative to X11/05
Leakage current:
Less than 1mA when output is off.
ON state:
Maximum output current:
150mA
Overcurrent protection:
Included, implemented by a resettable fuse.
Voltage drop X11/06 to X11/05:
Less than 2.5V, see below.
WARNING
WIRED CONNECTIONS TO TERMINALS X11/01, X11/03, X11/05 AND X11/06 MUST BE LESS THAN
25 METRES IN LENGTH AND REMAIN WITHIN THE CUBICLE OR DRIVE ENCLOSURE. PARKER
SSD DRIVES IS NOT LIABLE FOR ANY CONSEQUENCES IF EITHER CONDITION IS NOT MET.
Typical User Output Voltage Drop vs Current
0
0.5
1
1.5
2
2.5
0
20
40
60
80
100
120
140
160
Output current (mA)
O
ut
pu
t V
ol
ta
ge
D
ro
p