D-244
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
124.04 VELOCITY
MOVE TO
MASTER
REAL
0.10 to 300.00 %
1.00 %
rw
124.05 ACCELERATION
MOVE TO
MASTER
REAL
0.01 to 3000.00 %
1.00 %
rw
124.06 DIST TO MASTER
MOVE TO
MASTER
REAL
_.xxxx
0.0000
ro
Output
124.08 ACTIVE
MOVE TO
MASTER
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
124.09 STATE
MOVE TO
MASTER
ENUM
0 : RESET
1 : READY
2 : POS AQUIRE
3 : ALIGN
4 : DONE
READY
ro
Output
125.01 EMC CAPACITORS EMC
CAPACITORS
ENUM
0 : CONNECTED
1 : NOT CONNECTED
CONNECTED
rw
2
126.01 BAUDRATE
CANOPEN
ENUM
0 : 125K
1 : 250K
2 : 500K
3 : 1000K
125K
ro
Output
126.02 ADDRESS
CANOPEN
INT
_
0
ro
Output
126.03 STATUS RUN
CANOPEN
ENUM
0 : STOPPED
1 : PRE-OPERATIONAL
2 : OPERATIONAL
STOPPED
ro
Output
126.04 STATUS ERROR
CANOPEN
ENUM
0 : NO ERROR
1 : WARNING LIMIT
2 : AUTOBAUD OR LSS
3 : CONTROL EVENT
4 : SYNC. ERROR
5 : BUS OFF
NO ERROR
ro
Output
126.05 HARDWARE
CANOPEN
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output