Parameter Table: PREF Number Order
PREF Name
Block
Type
Range
Default
ro\rw Notes
1.03
TYPE
ANALOG INPUT 1 ENUM
0 : -10..+10 V
1 : 0..+10 V
-10..+10 V
rw
1.06
VALUE
ANALOG INPUT 1 REAL
_.x
100.0 %
ro
Output
2.03
TYPE
ANALOG INPUT 2 ENUM
0 : -10..+10 V
1 : 0..+10 V
-10..+10 V
rw
2.06
VALUE
ANALOG INPUT 2 REAL
_.x
100.0 %
ro
Output
3.03
TYPE
ANALOG INPUT 3 ENUM
0 : -10..+10 V
1 : 0..+10 V
2 : 0..20 mA
3 : 4..20 mA
-10..+10 V
rw
3.04
BREAK ENABLE
ANALOG INPUT 3 BOOL
0 : FALSE
1 : TRUE
FALSE
rw
3.05
BREAK VALUE
ANALOG INPUT 3 REAL
-300.00 to 300.00 %
0.00 %
rw
3.06
VALUE
ANALOG INPUT 3 REAL
_.x
100.0 %
ro
Output
3.07
BREAK
ANALOG INPUT 3 BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
4.03
TYPE
ANALOG INPUT 4 ENUM
0 : -10..+10 V
1 : 0..+10 V
2 : 0..20 mA
3 : 4..20 mA
-10..+10 V
rw
4.04
BREAK ENABLE
ANALOG INPUT 4 BOOL
0 : FALSE
1 : TRUE
FALSE
rw
4.05
BREAK VALUE
ANALOG INPUT 4 REAL
-300.00 to 300.00 %
0.00 %
rw
4.06
VALUE
ANALOG INPUT 4 REAL
_.x
100.0 %
ro
Output
4.07
BREAK
ANALOG INPUT 4 BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
5.06
VALUE
ANALOG INPUT 5 REAL
_.x
0.0 %
ro
Output