Programming
D-235
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
108.09 RESET
PHASE INCH
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
108.10 OFFSET
PHASE INCH
REAL
_.xxxx
0.0000
ro
Output
109.01 ENABLE
PHASE MOVE
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
109.02 DISTANCE
PHASE MOVE
REAL
-3000.0 to 3000.0
1.0
rw
109.03 DISTANCE FINE
PHASE MOVE
REAL
-1.0000 to 1.0000
0.0000
rw
109.04 VELOCITY
PHASE MOVE
REAL
0.10 to 300.00 %
1.00 %
rw
109.05 ACTIVE
PHASE MOVE
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
109.06 DISTANCE LEFT
PHASE MOVE
REAL
_.xx
0.00
ro
Output
109.07 ACCELERATION
PHASE MOVE
REAL
0.01 to 3000.00 %
1.00 %
rw
109.08 HOLD
PHASE MOVE
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
109.10 OFFSET
PHASE MOVE
REAL
_.xxxx
0.0000
ro
Output
109.11 RESET
PHASE MOVE
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
110.01 OFFSET
PHASE OFFSET
REAL
-3000.0 to 3000.0
0.0
rw
110.02 OFFSET FINE
PHASE OFFSET
REAL
-1.0000 to 1.0000
0.0000
rw
110.03 ACTIVE
PHASE OFFSET
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
110.04 SPEED OFFSET
PHASE OFFSET
REAL
-300.00 to 300.00 %
0.00 %
rw
111.01 PERIOD
PHASE TUNING
REAL
0.001 to 30.000 s
10.000 s
rw
111.02 ENABLE SPEED
PHASE TUNING
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
111.04 ENABLE PHASE
PHASE TUNING
BOOL
0 : FALSE
1 : TRUE
FALSE
rw