D-234
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
102.02 STOP TIME
REFERENCE
STOP
REAL
0.0 to 600.0 s
10.0 s
rw
102.03 STOP ZERO
SPEED
REFERENCE
STOP
REAL
0.00 to 100.00 %
0.10 %
rw
102.04 STOP DELAY
REFERENCE
STOP
REAL
0.000 to 30.000 s
0.500 s
rw
102.05 FAST STOP MODE REFERENCE
STOP
ENUM
0 : RAMP
1 : COAST
RAMP
rw
102.06 FAST STOP LIMIT
REFERENCE
STOP
REAL
0.0 to 3000.0 s
30.0 s
rw
102.07 FAST STOP TIME
REFERENCE
STOP
REAL
0.0 to 600.0 s
0.1 s
rw
102.08 FINAL STOP RATE REFERENCE
STOP
REAL
1 to 4800 Hz/s
1200 Hz/s
rw
103.01 SETPOINT
REFERENCE JOG REAL
-100.00 to 100.00 %
10.00 %
rw
103.02 ACCEL TIME
REFERENCE JOG REAL
0.0 to 3000.0 s
1.0 s
rw
103.03 DECEL TIME
REFERENCE JOG REAL
0.0 to 3000.0 s
1.0 s
rw
105.01 STALL TIME
STALL TRIP
REAL
0.1 to 3000.0 s
480.0 s
rw
3
105.03 STALL LIMIT TYPE STALL TRIP
ENUM
0 : TORQUE
1 : CURRENT
2 : TRQ OR CURRENT
TRQ OR CURRENT
rw
108.01 ADVANCE
PHASE INCH
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
108.02 RETARD
PHASE INCH
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
108.03 RATE
PHASE INCH
REAL
0.0001 to 30.0000
0.1000
rw
108.04 ACTIVE
PHASE INCH
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
108.08 RATE SCALE
PHASE INCH
REAL
0.001 to 30.000
1.000
rw