Programming
D-233
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
100.13 HOLD
REFERENCE
RAMP
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
100.14 RAMPING
REFERENCE
RAMP
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
101.01 REMOTE
SETPOINT
REFERENCE
REAL
-300.00 to 300.00 %
0.00 %
rw
101.02 SPEED TRIM
REFERENCE
REAL
-300.00 to 300.00 %
0.00 %
rw
101.03 MAX SPEED
CLAMP
REFERENCE
REAL
0.00 to 110.00 %
110.00 %
rw
101.04 MIN SPEED CLAMP REFERENCE
REAL
-110.00 to 0.00 %
-110.00 %
rw
101.05 TRIM IN LOCAL
REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
101.06 REMOTE REVERSE REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
101.07 COMMS SETPOINT REFERENCE
REAL
-300.00 to 300.00 %
0.00 %
rw
1
101.08 MAX SPEED
REFERENCE
REAL
0 to 32000 RPM
1500 RPM
rw
4
101.09 SPEED DEMAND
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.10 SPEED SETPOINT
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.11 REVERSE
REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
101.12 LOCAL SETPOINT
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.13 LOCAL REVERSE
REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
101.15 FWIRE SETPOINT
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.16 SPEED DEMAND
REFERENCE
REAL
_.x
0.0 Hz
ro
Output
102.01 RUN STOP MODE
REFERENCE
STOP
ENUM
0 : RUN RAMP
1 : COAST
2 : DC INJECTION
3 : STOP RAMP
RUN RAMP
rw