– 156 –
Chapter 8 System Menu — Maintenance settings
Maintenance settings
Software and hardware version
Version information
Information on the software and hardware versions of this unit can be displayed.
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Status] tab.
2
Check the [System Version] display in the [System Version] column.
f
Check the version of the overall system.
3
Check the display of the following columns.
[Main frame Soft1],
[Main frame Soft2],
[Main frame FPGA]
Check the versions of software and hardware of the Main Frame AV-HS60U1/AV-HS60U2.
[Main Panel Soft],
[Main Panel FPGA],
[Main Panel CPLD]
Check the versions of software and hardware of the main control panel.
[Sub Panel1 Soft],
[Sub Panel1 FPGA],
[Sub Panel1 CPLD]
Check the versions of software and hardware of the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/
AV-HS60C4).
[Sub Panel2 Soft],
[Sub Panel2 FPGA],
[Sub Panel2 CPLD]
Check the versions of software and hardware of the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/
AV-HS60C4).
Updates
Version of the software for the unit can be updated using a memory card.
For the latest software information and methods to upgrade the software version, refer to the following website.
http://pro-av.panasonic.net/ (English only)
Alarm
In this unit, the next alarm message will appear as a popup.
For error displays, the indicator part of [ALARM] in Menu Panel AV-HS60C3 is lit in red.
Alarm message
An alarm message is displayed in Menu Panel AV-HS60C3 when an alarm has occurred.
Alarm message
Type of trouble
Solution
[ALARM! Fan Stop]
Shutdown of the cooling fan
The alarm message disappears if [OK] is selected. Contact
your dealer immediately.
[ALARM! Power Failure]
Power supply problem
[ALARM! Temperature]
Rise in the temperature inside the unit
Alarm status displays
The next hardware alarm can be checked from the <SYS> button
→
[MAINTENANCE]
→
[Alarm] tab page. This page can be displayed even if
[ALARM] of the Menu Panel AV-HS60C3 is selected.
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Alarm] tab.
2
Check the display of each item in the [Main frame]/[Main Panel]/[Sub Panel1]/[Sub Panel2] column.
[Power A]
Displays the status of problems in the cooling fan or power inside the power supply 1.
[Power B]
Displays the status of problems in the cooling fan or power inside the power supply 2.
[Fan]
Displays the problem status of the cooling fan. It is displayed in the [Main frame] column.
[Temperature]
Displays the problem status of the internal temperature.
r
Display details
[No Alarm]
Shows that there are no problems.
[Alarm]
Shows that there is a problem.
[
−
]
Not a target for determination.
f
When a power supply unit is not mounted
f
When [Off] is selected in each item of [Alarm Enable]
Enabling/disabling the alarm display
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Alarm] tab.
Summary of Contents for AV-HS60C1E
Page 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Page 52: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Page 162: ...This chapter describes the difference with the Standard mode Chapter 9 3G mode 4K mode ...