READ:
-8.2
6.3.3.23 SOURce:ONECHN:CONTrol
Function
Control the execution of the Signal Generator.
Command Syntax
SOURce:ONECHN:CONTrol <START|STOP|ARM>
Parameter
enum {START,STOP,ARM}
Example
SEND:
SOURce:ONECHN:CONTrol start
6.3.3.24 SOURce:ONECHN:CONTrol?
Function
Query the current state of the Signal Generator. Meaning of returned values is the fol-
lowing:
START
: Signal Generator is started and running
STOP
: Signal Generator is stopped and thus not running
WAIT
: Signal Generator delays startup for 2 minutes to allow the simulation to load
required data. The start time derived from the NTP server is then aligned to the next
full GPS minute.ARMED: Signal Generator is armed, all data loading is done, but Sig-
nal Generator is not yet running, but waiting for the trigger to start it
ARMING
: Signal Generator is loading data to memory, and arming after which it
transitions to the ARMED state
Command Syntax
SOURce:ONECHN:CONTrol?
6.3 Command Reference
User Manual GSG-5/6 Series Rev. 27