OPTICAL SYSTEMS DESIGN
DOC ID: 10118101
OSD2512 OPERATOR MANUAL
PAGE 371
PTP
Monitor
PTP
This page allows the user to inspect the current PTP clock settings.
PTP EXTERNAL CLOCK DESCRIPTION
One_PPS_Mode
Shows the current One_pps_mode configured.
1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put
External Enable
Shows the current External clock output configuration.
1. True : Enable the external clock output
2. False : Disable the external clock output
Adjust Method
Shows the current Frequency adjustment configuration.
1. LTC frequency : Local Time Counter (LTC) frequency control
2. SyncE-DPLL : SyncE DPLL frequency control, if allowed by SyncE
3. Oscillator : Oscillator independent of SyncE for frequency control, if supported by the HW
4. LTC phase : Local Time Counter (LTC) phase control (assumes that the frequency is locked
by means of SyncE)
Clock Frequency
Shows the current clock frequency used by the External Clock.
The possible range of values are 1 - 25000000 (1 - 25MHz)