PTP CLOCK DESCRIPTION
Inst
Indicates the Instance of a particular Clock Instance [0..3].
Click on the Clock Instance number to monitor the Clock details.
ClkDom
Indicates the Clock domain used by the Instance of a particular Clock Instance [0..3].
Device Type
Indicates the Type of the Clock Instance. There are five Device Types.
1. Ord-Bound - Clock's Device Type is Ordinary-Boundary Clock.
2. P2p Transp - Clock's Device Type is Peer to Peer Transparent Clock.
3. E2e Transp - Clock's Device Type is End to End Transparent Clock.
4. Master Only - Clock's Device Type is Master Only.
5. Slave Only - Clock's Device Type is Slave Only.
Port List
Shows the ports configured for that Clock Instance.
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
: Click to refresh the page immediately