OPTICAL SYSTEMS DESIGN
DOC ID: 10118101
OSD2512 OPERATOR MANUAL
PAGE 174
Nominated
When a clock source is nominated, the clock output from the related PHY (Port) is enabled
against the clock controller. This makes it available as a possible source in the clock selection
process. If it is supported by the actual HW configuration, The Station clock input can be
nominated as a Clock Source.
Port
In this drop down box, the ports that are possible to select for this clock source, is presented.
The PCB104 Synce module supports 10MHz station clock input. The station clock input is
indicated by a port name = 'S-CLK'. The serval1 has a limitation that chip port 1 cannot be
nominated as source 1. On the Vitesse boards this is port 7 (interface gi 1/7).
Serval2 NID board limitations: Port 5-12 can be configured for 100M, 1G or 2.5G speed. In
2.5G speed mode the SyncE hardware is not able to lock, because the recovered clock output
frequency does not match the SyncE hardware's frequency options.
Priority
The priority for this clock source. Lowest number (0) is the highest priority. If two clock
sources has the same priority, the lowest clock source number gets the highest priority in the
clock selection process.
SSM Overwrite
A selectable clock source Quality Level (QL) to overwrite any QL received in a SSM. If QL is
not Received in a SSM (SSM is not enabled on this port), the SSM Overwrite QL is used as if
received. The SSM Overwrite can be set to QL_NONE, indicating that the clock source is
without any know quality (Lowest compared to clock source with known quality)
Hold Off
The Hold Off timer value. Active loss of clock Source will be delayed the selected amount of
time. The clock selector will not change clock source if the loss of clock condition is cleared
within this time
ANEG Mode
This is relevant for 1000BaseT ports only. In order to recover clock from port it must be
negotiated to 'Slave' mode. In order to distribute clock the port must be negotiated to 'Master'
mode.
This different ANEG modes can be activated on a Clock Source port:
Prefer Slave:
The Port will be negotiated to 'Slave' mode if possible.
Prefer Master:
The Port will be negotiated to 'Master' mode if possible.
Forced Slave:
The Port will be forced to 'Slave' mode.
The selected port in 'Locked' state will always be negotiated to 'Slave' if possible.
LOCS
Signal is lost on this clock source.
SSM
If SSM is enabled and not received properly. Type of SSM fail will be indicated in the 'Rx
SSM' field
WTR
Wait To Restore timer is active.
Clear WTR
Clears the WTR timer and makes this clock source available to the clock selection process.