OPTICAL SYSTEMS DESIGN
DOC ID: 10118101
OSD2512 OPERATOR MANUAL
PAGE 283
Event Seconds Summary Window
This two-octet field indicates the duration of the period in terms of 100 ms intervals, encoded
as a 16-bit unsigned integer.
Event Seconds Summary Threshold
This two-octet field indicates the number of errored frame seconds in the period is required to
be equal to or greater than in order for the event to be generated, encoded as a 16-bit unsigned
integer.
Event Seconds Summary Events
This two-octet field indicates the number of errored frame seconds in the period, encoded as a
16-bit unsigned integer.
Event Seconds Summary Error Total
This four-octet field indicates the sum of errored frame seconds that have been detected since
the OAM sublayer was reset.
Event Seconds Summary Event Total
This four-octet field indicates the number of Errored Frame Seconds Summary Event TLVs
that have been generated since the OAM sublayer was reset, encoded as a 32bit unsigned
integer.
Buttons
The port select box determines which port is affected by clicking the buttons.
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
: Click to clear the data.
: Click to refresh the page immediately.