OPTICAL SYSTEMS DESIGN
DOC ID: 10118101
OSD2512 OPERATOR MANUAL
PAGE 281
DETAILED LINK OAM LINK STATUS FOR PORTS
Monitor
Link OAM
Event Status
This page allows the user to inspect the current Link OAM Link Event configurations,
and change them as well.
The left pane displays the Event status for the Local OAM unit while the right pane
displays the status for the Peer for the respective port.
Port
The switch port number.
Sequence Number
This two-octet field indicates the total number of events occurred at the remote end.
Frame Error Event Timestamp
This two-octet field indicates the time reference when the event was generated, in terms of
100ms intervals.
Frame error event window
This two-octet field indicates the duration of the period in terms of 100 ms intervals. 1) The
default value is one second. 2) The lower bound is one second. 3) The upper bound is one
minute.
Frame error event threshold
This four-octet field indicates the number of detected errored frames in the period is required
to be equal to or greater than in order for the event to be generated. 1) The default value is one
frame error. 2) The lower bound is zero frame errors. 3) The upper bound is unspecified.
Frame errors
This four-octet field indicates the number of detected errored frames in the period.