101
Z500
Operation Manual
SECTI
ON 4
SECTION 4
Menus for Expert Menu
Outputting Profile Data
Analog waveforms of the data on height of 126 lines are output.
The asterisk (*) indicates the default setting.
Note:
The range of profile varies depending on the Sensor connected.
Example:
Z500-SW17
CHECK
Refer to page 181 for details on output timing.
CHECK
The setting can be performed through the adjustment menu.
REFERENCE
Refer to page 28.
Item
Selection
Description
Output
OUT0 to OUT7
Profile
(OUT0*)
Select
Profile
.
Profile
(See note.)
Select the output range of profile data.
F.S.*
The output covers the whole measurement range.
1/2F.S.
The output covers one-half of the measurement
range.
1/4F.S.
The output covers one-quarter of the measurement
range.
Selection
Output range
F.S.
-20mm to +20mm
1/2F.S.
-10mm to +10mm
1/4F.S.
-5mm to +5mm