97
Z500
Operation Manual
SECTI
ON 4
SECTION 4
Menus for Expert Menu
Judgment value hysteresis width (judgement width)
Set the hysteresis width for Judgment limits.
The default setting varies depending on the Sensor connected.
Edge Detection Hysteresis Width (Edge width)
Set the hysteresis width of edge detection.
Change the edge width when edge detection is unstable.
The asterisk (*) indicates the default setting.
Smoothing
(Smoothing)
Use this function to smooth the measured images.
The asterisk (*) indicates the default setting.
Noise removal
(Noise)
Other than images with a setting pixel will be regarded as noise and excluded
from measurement.
The asterisk (*) indicates the default setting.
Setting range
0.00000 to 9999.99999
HI
(100.0000)
LO
(80.0000)
HIGH
OFF
ON
OFF
ON
OFF
ON
LOW
PASS
Hysteresis(0.0500)
Hysteresis(0.0500)
Resets at 80.0500 mm
Output
Resets at 99.9500 mm
Example:
HI:
100.000 mm; LO: 80.000 mm
Judgment value hysteresis width: 0.05 mm
Setting range
0.00000 to 9999.99999 (0.00000*)
Edge level
(80.0000)
Hysteresis (0.0500)
Edge position
Example:
Edge level: 80.000 mm
Edge level hysteresis width: 0.0500 mm
Selection
Description
None
No smoothing.
Weak*
Smoothing is performed at a low level.
Strong
Smoothing is performed at a high level.
Selection
0pixel, 1pixel, 2pixel, 3pixel, 4pixel*, 5pixel, 6pixel, 7pixel,
St
e
p
2
St
e
p
1
St
e
p
3
St
e
p
4
St
e
p
5
St
e
p
6
St
e
p
7