SECTION 5
Other Functions
5-3-3 Changing the Trend Monitor's Display Contents
Change the screen mode, the waveform display range, and the waveform display time.
REFERENCE
Refer to page 29 for details on the contents of display on the screen.
The asterisk (*) indicates the default setting.
Note:
The contents to be set are also used for the Profile Monitor. The contents that
have been finally set will become effective.
Thru
1div x: 1.000 [s]
y:+10.0000[mm]
9.96ms
Scn 0 Run
Vertical setting
Maximum display value
Minimum display value
Mode
Horizontal setting (Display time)
Conversion values for X and Y axes
The units corresponding to 1 division (1 div)
on the waveform display are displayed.
If the setting is changed, the display
also changes.
Use these values as reference when
setting the values.
1div x: 1.000
y:+10.000
1div
x
y
Item
Selection/Setting
Description
Mode
(See note.)
Thru*
Displays the waveform obtained by the Sensor
continuously.
Trig
Displays a still waveform corresponding to the
trigger timing. (Updated when the trigger turns ON.)
Vert
-9999.99999 to
9999.99999
Sets the maximum and minimum values displayed
on the screen.
Different values can be set for each output number.
The default setting varies depending on the Sensor
model connected.
Horiz
(See note.)
1.00 to 30.00s
(5.00s*)
Sets the display time (X axis) for the waveform
displayed on the screen.