Z500
Operation Manual6
SECTION 3
43
SECTION 3
Menus for Conversational Menu
#2
Setting the Measurement Region
Specify the region to be measured.
The Z500 adjusts sensitivity and performs measurements in a region that has been previously set.
Though the whole image can be used for the measurement region, measurement accuracy can be
raised by specifying a restricted measurement region.
Position the workpiece correctly and specify the measurement region.
CHECK
Correct measurement may not be possible at the boundaries of the measurement regions.
Leave space at the boundaries when setting the regions.
1.
Position the workpiece correctly while
monitoring the profile graph.
2.
Press the
ENT
Key.
The screen for specifying the region will be displayed.
3.
Specify the starting line of the
measurement region.
The cursor will be moved to the ending line.
4.
Repeat the procedure described in
(
3
.) to specify an ending line and press the
ENT
Key.
Go to
#3
.
Select the Sensitivity Adjustment Method
.
Profile
ENT:Next ESC:Back
Measurement image displayed.
Check workpiece position.
Cursor
ENT:Next ESC:Back
Sen0's measurement region
Strt+0023.597mm Stp -0023.983mm
Strt
0lines Stp
125lines
St
e
p
2
St
e
p
1
St
e
p
3
St
e
p
4
St
e
p
5
St
e
p
6