130
SECTION 5
5-6 T
estin
g Mea
s
ureme
n
t Performan
ce (T
est)
Z500
Operation Manual
SECTION 5
Other Functions
CHECK
Up to 5 sets of measurement results can be displayed in list format. This feature is useful
for the following.
• Comparing measurements for different items
• Comparing the still state and moving state
• Evaluating repeat accuracy
Item
Description
NUM
Displays the number of measurements performed during the test
measurement period.
AVE
Displays the average measurement value for the test measurement
period.
MAX-MIN
Displays the maximum and minimum measurement values for the test
measurement period.
MAX
Displays the maximum measurement value for the test measurement
period.
MIN
Displays the minimum measurement value for the test measurement
period.
OUT0
MAX-MIN
+0000.01821
+0000.01821
No.
1
2
3
4
5
AVE
-0004.05122
-0004.05122
NUM
100
100
-0004.03975mm [ STOP ]
Scn 0 Tools
OUT0 -0004.03975mm [STOP]
MIN
+0004.05770
+0004.05770
No.
1
2
3
4
5
MAX
-0004.03948
-0004.03948
NUM
100
100
Scn 0 Tools
Output number
The output number being tested is displayed.
Press the
Up
and
Down
Keys to change the number.
Measurement results
Measurement status
During measurement, [RUN] flashes.
Test results
The most recent test results are displayed in reverse video.
After the 5th measurement, the previous results
are overwritten in order starting from 1.
Switch display items