Z500
Operation Manual
SECTION 4
Menus for Expert Menu
Setting Measurement Region
Specify the region to be measured.
The Z500 adjusts sensitivity and performs measurements in a region that has
been previously set. Though the whole image can be used for the measurement
region, measurement accuracy can be raised by specifying a restricted
measurement region.
CHECK
Correct measurement may not be possible at the boundaries of the measurement regions.
Leave space at the boundaries when setting the regions.
1.
Select
Image/Region.
The screen for specifying the region will be displayed.
2.
Specify the starting line of the
measurement region.
Move the cursor with the
Up
and
Down
Keys.
(Use these keys together with the
SHIFT
Key to move the cursor quickly.)
The cursor will be moved to the ending line.
3.
Repeat the procedure described in
(
2.
)
to specify the ending line of the
measurement region.
A confirmation message will be displayed.
4.
Select
Execute
.
The setting will be registered and the screen in
(
1.
)
will return.
Image
Compensatn
Meas set
Conditions
Output
Meas method
Region
Sensitivity
Details
Scn 0 Set
Cursor
The measurement region
will be set. OK?
Execute
Cancel