Z500
Operation
Manual
7-2 R
S
-232C
SE
CTION 7
169
SECTION 7
I/O Format
Example
• ZERO
Function 1
……
Executes Force-zero.
ZERO 0 <Output number> <Offset value>
• Specify an output number between 0 and 8.
• Set the offset value used for Force-zero execution. Set the value to be added
to 0 in the range -9999.99999 to 9999.99999. If this setting is omitted, the
offset value that is already set will be used.
Command executed correctly
: OK
Command not executed correctly
: ER
Example
: SENSM 18 24 160
The sensitivity level will be automatically adjusted to 18 to 24 so that
a light receiving level of 160 is satisfied.
: OK
Input
delimiter
Output
delimiter
Output number
Meaning
0
OUT0
1
OUT1
2
OUT2
3
OUT3
4
OUT4
5
OUT5
6
OUT6
7
OUT7
8
All zero
Input
delimiter
Output
delimiter
delimiter
:
ZERO 0 1
Force-zero is executed for OUT1.
:
OK
Input
delimiter
Output
delimiter