The procedure for make trigger settings under the following details is explained
below.
Operational Flow
#1
Display Waveforms in the Trend Monitor
Use the waveform to decide the trigger level and to set the measurement start
position.
CHECK
Set the screen mode to
Thru
in advance.
REFERENCE
Refer to page 118.
1.
Press the
SHIFT
+
Right
Keys or
SHIFT
+
Left
Keys several times to switch to
Trend Monitor.
2.
Pass the workpiece under the Sensor
and display the waveform.
3.
The instant the waveform representing
the workpiece is displayed, press the
TRIG
Key.
The waveform display is fixed.
Trigger input method
Self
Hold setting (see note)
Peak-Peak
Measurement item
OUT0
:
Height
OUT0
Refer to page 84.
The difference between the maximum value and minimum value of the workpiece height is output.
Note:
Set the Hold setting by using
Meas
set
in advance.
Display Waveforms
in the Trend Monitor
(Through Mode)