72
SECTI
ON 4
Step: 2 pts
Z500
Operation Manual
SECTION 4
Menus for Expert Menu
Step: 2 pts
Level differences, grooves, etc. of workpieces are measured.
The following conditions will be taken as an example for describing the setting procedures.
1.
Select
Meas set.
A list of output numbers will be displayed.
2.
Select the output number for which
Step: 2 pts
is set.
In this example, Select
OUT1.
CHECK
Height
is set in
OUT0
as the default set-
ting. To set an item other than
Height
in
OUT0
, delete the existing measurement item.
REFERENCE
Refer to page 87.
The selection for measurement item will be displayed.
3.
Select the measurement item.
In this example, select
Step: 2 pts
.
Measurement
point (Average)
Measurement
point (Average)
Top face region
Bottom face region
Image
Compensatn
Meas set
Conditions
Output
Scn 0 Set
OUT0:Height
OUT1:
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
Scn 0 Set
Measrmnt item
Height
Step: 2 pts
Step: 3 pts
Edge position
Width
Edge center
Peak/bottom
Define