166
7-2 R
S
-232C
SE
CTION 7
Z500
Operation
Manual
SECTION 7
I/O Format
• SENS
Function 1
……
Sets the sensitivity adjustment method to
Auto
and obtains the
optimum sensitivity for the workpiece.
SENS
Command executed correctly
: Sensitivity level (1 to 31)
Command not executed correctly
: ER
Example
Function 2
……
Sets the sensitivity adjustment method to
Auto
and changes the
sensitivity level, turns the Laser OFF, and changes adjustments gradation.
SENS <Sensitivity level A> <Sensitivity level B> <Adjustment
gradation >
Specify values between 0 and 31 for sensitivity level A and sensitivity level B.
• The sensitivity is set to the optimum level between A and B. Do not set A to a
value larger than B.
• If the same value is set for A and B, the sensitivity will be fixed at that level.
• If both A and B are set to 0, the laser will turn OFF.
(However, a measurement error will be exhibited.)
As a target value of the sensor sensitivity adjustment gradation, specify 120 to
220. If this setting is omitted, the gradation will be set to 170 (default setting).
CHECK
Laser OFF Delay Time
The total time required for turning OFF the laser is less if terminal block input is used.
If the laser must be turned OFF instantaneously, use the LD-OFF input terminal.
REFERENCE
Refer to page 154 for information on how to input terminals.
Command executed correctly
: OK
Command not executed correctly
: ER
Example
Input
delimiter
Output
delimiter
delimiter
: SENS
: 17
The optimum sensitivity is 17.
Input
delimiter
Output
delimiter
Input
delimiter
Output
delimiter
delimiter
:
SENS 18 24 160
The sensitivity level will be automatically adjusted to 18 to 24 so that a light
receiving level of 160 is satisfied.
: OK
Input
delimiter
Output
delimiter