5-3-4 Changing the Profile Monitor's Display Contents
Change the screen mode, the waveform display range, the waveform display
time, and cursor positions on profile and trend display.
REFERENCE
Refer to page 29 for details on the contents of display on the screen.
The asterisk (*) indicates the default setting.
Note:
The contents to be set are also used for the Trend Monitor. The contents that
have been finally set will become effective.
9.96ms
1div x: 1.000 [s]
y:+10.0000[mm]
Thru
Scn 0 Run
Maximum display value
Minimum display value
1div x: 1.000
y:+10.000
1div
x
y
Vertical setting
Mode
Horizontal setting
(Display time)
Conversion values for X and Y axes
The units corresponding to 1 division (1 div)
on the waveform display are displayed.
If the setting is changed, the display
also changes.
Use these values as reference when
setting the values.
Profile cursor
Trend cursor
Item
Selection/Setting
Description
Mode
(See note.)
Thru*
The shaded 3-D image acquired through the
Sensor will be displayed continually.
Trig
A shaded 3-D image will be displayed in response
to the trigger timing.
(Updated when the trigger turns ON.)
Vert
-9999.99999 to
9999.99999
Sets the maximum and minimum values displayed
on the screen.
The default setting varies depending on the Sensor
model connected.
Horiz
(See note.)
1.00 to 30.00s
(5.00s*)
Sets the display time (X axis) for the waveform
displayed on the screen.
Move cursr
Sets the profile and trend display positions.