![background image](http://html1.mh-extra.com/html/omron/z500-series/z500-series_operation-manual_743394076.webp)
74
SECTI
ON 4
Ed
ge p
o
sit
ion
Z500
Operation Manual
SECTION 4
Menus for Expert Menu
Edge position
Measures the edge position of the workpiece.
The following conditions will be taken as an example for describing the setting procedures.
In this example, the intersection point of the edge level and the profile becomes
the measurement point.
Set the edge level as follows.
CHECK
The setting edge level and the measurement point can be checked on the Image Monitor.
REFERENCE
Refer to page 32.
1.
Select
Meas set.
A list of output numbers will be displayed.
2.
Select the output number for which
Edge position
is set.
In this example, select
OUT2.
CHECK
Height
is set in
OUT0
as the default
setting. To set an item other than
Height
in
OUT0
, delete the existing measure-
ment item.
REFERENCE
Refer to page 87.
Measurement
point (Edge position)
Edge level
Edge level
Profile
The intersection is
the measurement point.
Image
Compensatn
Meas set
Conditions
Output
Scn 0 Set
OUT0:Height
OUT1:
Step: 2 pts
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
Scn 0 Set