SECTION 7
I/O Format
• SLANTSAVE
Function
……
Saves correction values to a host device.
SLANTSAVE
• The data transfer is performed with XMODEM(-CRC or SUM) protocol.
The XMODEM(-1K) protocol is not supported.
• The Z500 sends a READY signal to the host device when the Z500 has
completed its initialization. Wait for the READY signal to be received at the
host device before starting the data transfer.
• The following four types of data will be saved in block.
- For Sensor 0 (Wide) - For Sensor 0 (Zoom)
- For Sensor 1 (Wide) - For Sensor 1 (Zoom)
Command executed correctly
: OK
Command not executed correctly
: ER
Example
• SYSLOAD
Function
……
Loads system data from a host device to the Z500.
SYSLOAD
• The data transfer is performed with XMODEM(-CRC or SUM) protocol. The
XMODEM(-1K) protocol is not supported.
• The Z500 sends a READY signal to the host device when the Z500 has
completed its initialization. Wait for the READY signal to be received at the
host device before starting the data transfer.
Data correctly loaded
: OK
Data not correctly loaded
: ER
Example
Input
delimiter
Output
delimiter
delimiter
:
SLANTSAVE
Correction values will be saved to the host device.
:
OK
Input
delimiter
Output
delimiter
Input
delimiter
Output
delimiter
delimiter
:
SYSLOAD
This example loads the system data from the host device.
:
OK