70
SECTI
ON 4
4-1 Setting
Measurem
e
nt Con
d
it
ion
s
Using
th
e Expert Menu
s
Z500
Operation Manual
SECTION 4
Menus for Expert Menu
Step
4
Measurement Settings
Set the measurement contents. Operational flow varies depending on the measurement item.
Setting
Step: 2 pts
,
Edge position
, and
Define
are taken as examples for description.
Operational Flow
CHECK
To use the position compensation function, set
Compensatn
and
Meas set
in this order.
CHECK
The settings can be performed through the adjustment menu.
REFERENCE
Refer to page 28.
#1
Set Measurement Items
Up to eight measurement contents can be set for each scene.
There are 8 types of the measurement item. Different measurement item can be
set for each output number.
Types of Measurement Item
*
Height
is set in
OUT0
as the default setting.
Set Output
Conditions
Changing
Measurement
Contents
Clearing
Measurement
Items
Set Measurement
Items
#1
Page 70
Page 86
Page 87
Set Calibration
#2
Page 78 (if necessary)
#3
Page 84 (if necessary)
When selecting
Define
:
When not
selecting
Define
:
#2
Calibration setting is disabled.
Compensate the measurements under the output conditions given in
#3
.
Selection
Description
Symbol
Height*
Measure the height within the specified region.
Step: 2 pts
Specify two measurement regions.
After taking the measurement point within the 1st region
as the reference, measure the distance from the mea-
surement point in the 2nd region.
REFERENCE
Refer to page 72.
Step: 3 pts
Specify three measurement regions.
After taking the average of the measurement points
within the two regions specified above, measure the
difference from the measurement point in the 3rd region.
Edge position
Measures the specified edge position.
REFERENCE
Refer to page 74.