Compensate the Measured Level Difference and Width
To compensate for the error, perform the measurement once.
Applicable measurement items: Step: 2 pts, Step: 3 pts, Width
1.
Move the cursor to
Step: 2 pts
and
press the
ENT
Key.
The selections will be displayed.
2.
Select
Calibrate
.
5mm
5mm
4.95mm
Measure with the
workpiece in position.
0mm
Compensate for this error.
Measurement value
Calibrate to 5 mm.
Point 1
Point 2
Level difference: 5 mm
Use the method shown below to calibrate workpieces so that a displacement value of 4.95 mm is
measured as 5 mm.
Input the value
of point 1.
5mm
Example
: When selecting
Step: 2 pts
To compensate for this error, perform the measurement once.
Input the value
of point 2.
Level difference of workpiece