![background image](http://html1.mh-extra.com/html/omron/r6yxc1000/r6yxc1000_user-manual_742791186.webp)
A
Troubleshooting
A-4
1.1.2
Alarm classification number list
Alarm code
Type
Axis operation
in case of error
History
LED
display
Reset method
Example
0
Correct
-
-
Not
displayed
-
-
1 to 99
Message
Restart operation
HALT, HOLD, Break point,
Key release
100 to 199
Save
CPU start
200 to 399
Operation
error
Individual
operation stop
Restart
corresponding
operation
No point
400 to 499
Operation stop
Display
Interlock
500 to 599
External
error
Reset command
PIO24V off, SIO link error
600 to 699
Servo brake
Emergency stop, Main power off
700 to 799
Internal
error
Operation stop
Fan error
800 to 899
Servo brake
Overload
900 to 999
Immediate
servo off
Restart system
Over-current,
Driver communication failure
1.1.3
Warning number list
Warning
number
Type
Axis operation
in case of error
History
LED
display
Reset method
Example
c1 to c99
General
warning
-
-
Warning
Status
Remove the warning cause.
Overload warning
[ 0] Operation messages
0.0 : OK
Code
: &H0000 &H0000
Meaning/Cause
Correct status. No alarm occurs.
Action
−−−
0.2 : Running
Code
: &H0000 &H0002
Meaning/Cause
A program or command is running.
Action
−−−
0.5 : Busy
Code
: &H0000 &H0005
Meaning/Cause
The data is being saved.
Action
−−−
0.8
: Try again
Code
: &H0000 &H0008
Meaning/Cause
The operation failed.
Action
Try again.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...