6
Exter
nal comm
unica
tion interf
ace
6-11
3.2 Communication specifications
Specification item
Type
Ethernet applicable unit
Network specifications
In conformity with Ethernet (IEEE802.3)
Communication speed
100 Mbps (100BASE-TX)
Connector specifications
RJ-45 connector (8 modular connectors)
Cable specifications
UTP cable (non-shielded twist pair cable) or STP cable (shielded twist pair cable)
applicable to category 5 or higher
Maximum cable length
100 m (between hub and controller)
Communication mode
Full duplex
Network protocol
Application layer
: TELNET
Transport layer
: TCP
Network layer
: IP, ICMP, ARP
Data link layer
: CSMA/CD
Physical layer
: 100BASE-TX
Number of simultaneous log-in cycles
1
IP address setting
Setting is made from the programming box or support software
"SCARA-YRCX Studio".
Monitor LED
Link/Activity, Speed
IP address initial value
192.168.0.2
Subnet mask initial value
255.255.255.0
Default gateway initial value
192.168.0.254
CAUTION
OMRON uses FL HUB (PHOENIX CONTACT) for the operation check. When incorporating a system, it is
recommended to use this hub. It is not assumed to use general consumer hubs at factory. Such hubs may have
low noise immunity.
NOTE
Refer to the SCARA-YRCX Studio manual for details on how to set the IP address.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...