![background image](http://html1.mh-extra.com/html/omron/r6yxc1000/r6yxc1000_user-manual_742791226.webp)
A
Troubleshooting
A-44
12.601: Illegal operation mode input
Code
: &H000C &H0259
Meaning/Cause
a. The programming box or terminator is not connected to the PB connector,
b. Settings of the MANUAL LOCK of the programming box and AUTO MODE of the SAFETY
connector are incorrect in the case of a CE specification controller.
Action
a. Connect the programming box or terminator to the PB connector.
b. Check the AUTO MODE connection of the SAFETY connector in the case of a CE specification
controller.
12.700: Option board changed
Code
: &H000C &H02BC
Meaning/Cause
The option board configuration was changed.
Action
Initialize the option board setting.
12.705: Parallel I/O board assign changed
Code
: &H000C &H02C1
Meaning/Cause
a. The PIO board was pulled out, or new one was inserted.
b. "Option board enable" parameter was changed.
c. "Parallel IO ID" parameter was changed.
d. PIO board is damaged.
Action
a. Check if the PIO board configuration is correct.
b. Check if the option board configuration is correct.
c. Check the PIO board IDs are correct.
d. Check unrecognizable PIO boards and replace them.
12.706: PIO board I/O stop
Code
: &H000C &H02C2
Meaning/Cause
a. PIO board power is turned off or has stopped operation.
b. The PIO board is broken.
Action
a. Check if power for the PIO board is supplied normally.
b. Replace the PIO board.
12.734: POS.OUT Point not exist
Code
: &H000C &H02DE
Meaning/Cause
Comparison point data does not exist.
Action
Set the comparison point data correctly.
12.735: POS.OUT Point unit error
Code
: &H000C &H02DF
Meaning/Cause
Comparison points 1 and 2 do not use the same unit system.
Action
Change them to the same unit system.
12.750: PIO board Flash error
Code
: &H000C &H02EE
Meaning/Cause
The PIO board is breakdown.
Action
Replace the PIO board.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...