A
Troubleshooting
A-68
1.2 Alarm messages related to the programming box
If a hardware or software error occurs in the programming box, relevant message appears on the screen.
NO PANEL DATA
Meaning/Cause : Screen data could not be downloaded during upgrading.
Action
: Perform the upgrading again.
Receiving Error.
Meaning/Cause : Error occurred during data receiving.
Specified communication was not performed within the specified period of time.
Action
: Check the communication cable for abnormality.
Check that the connector is inserted correctly.
Sending Error.
Meaning/Cause : Error occurred during data sending.
CTS signal did not turn on for 5 seconds during data sending.
Action
: Check the communication cable for abnormality.
Check that the connector is inserted correctly.
Receiving timeout.
Meaning/Cause : Error occurred during data receiving.
Specified communication was not performed within the specified period of time.
Action
: Check the communication cable for abnormality.
Check that the connector is inserted correctly.
NG=xx.xxx
Meaning/Cause : Alarm occurred in the controller.
Action
: Check the alarm contents and perform the alarm reset.
No breakpoint set.
Meaning/Cause : Break point was not set in the program debug.
Action
: Set a break point.
USB IO ERROR
Meaning/Cause : USB memory device was not supported.
Action
: Replace the USB memory device with a correct one.
USB Not Connect
Meaning/Cause : USB memory device was not connected or a device other than the USB memory device was
connected.
Action
: Connect the USB memory device correctly.
Bad Format
Meaning/Cause : Format of the USB memory device was incorrect.
Action
: Change the format of the USB memory device to FAT16 or FAT32.
Not FAT16 Format
Meaning/Cause : Format of the USB memory device was NTFS.
Action
: Change the format of the USB memory device to FAT16 or FAT32.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...