7-30
■
PROFIBUS station address
‹
PBUSADD
›
This parameter sets the station number (the identifier to each node of the PROFIBUS) of the PROFIBUS-corresponding
unit. The setting range is between 1 and 125. When this parameter is initialized, "125" is set.
New setting value will be valid after turning off and on the power.
■
Gripper servo when emergency stop
‹
GEMGMD
›
This parameter sets the gripper servo status when the emergency stop button is pressed. When this parameter is
initialized, "1: ON" is set.
Setting
Meaning
0: OFF
The remote command cannot be used.
1: ON
The gripper servo is not turned off when the emergency button is pressed. Therefore, the gripper
keeps to grip the workpiece.
■
Include Gripper in Origin
‹
GORGMD
›
This parameter sets whether the gripper is added to the axes when return-to-origin operation of the entire robot.
When this parameter is initialized, "1: YES" is set.
The following operations enable this parameter:
• Return-to-origin by DI14 or DI17
• Return-to-origin by the programming language (ORIGIN)
• Return-to-origin by remote command
Setting
Meaning
0: NO
The gripper is not added to the axes to be performed return-to-origin.
* Executes the online command @GORIGIN to perform return-to-origin of the gripper.
1: YES
The gripper is added to the axes to be performed return-to-origin.
■
Manual Holding of Gripper
‹
GMHLMD
›
This parameter sets whether the gripper holds the workpiece by the jog movement online command (@GJOG, @GJOGXY).
When this parameter is initialized, "1: VALID" is set.
Setting
Meaning
0: INVALID
The jog movement online command (@GJOG, @GJOGXY) is INVALID. If the gripper holds
the workpiece, "26.801: Gripper over load" alarm occurs.
1: VALID
The jog movement online command (@GJOG, @GJOGXY) is VALID.
■
Gripper origin sequence
‹
GORGORD
›
This parameter sets the order of return-to-origin for the gripper to decide the motor position. When this parameter is
initialized, "1234" is set, and each number is corresponding to the gripper numbers.
Return-to-origin operations of the grippers are performed from the left end of the return-to-origin order setting in order.
The grippers without setting perform return-to-origin simultaneously at last.
■
Gripper origin priority
‹
GORGPRI
›
This parameter sets the timing of performing return-to-origin of the gripper. When this parameter is initialized, "0: AFTER"
is set.
Setting
Meaning
0: AFTER
Return-to-origin of the gripper is performed after all the robots return-to-origin.
1: BEFORE
Return-to-origin of the gripper is performed before all the robots return-to-origin.
Summary of Contents for R6YXC1000
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 86 5 6 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 54: ......
Page 56: ......
Page 64: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 108: ......
Page 110: ......
Page 136: ......
Page 168: ......
Page 170: ......
Page 174: ...8 Periodic inspection 8 4...
Page 176: ......
Page 182: ......
Page 256: ......
Page 258: ......
Page 259: ......
Page 260: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...